What was found
WHILE ACCOMPLISHING E.O.T1-5340-117249B-P4, FOUND RIGHT HAND NOSE LANDING GEAR TRUNNION FITTING HAVE CRACKED AT STATION Y = 595. RIGHT HAND NOSE LANDING GEAR TRUNION FITTING AT STATION Y = 595 CRACKED REPAIR CARRIED OUT AS PER MD-11 SRM 53-10-14-2R FIGURE 202 REPAIR 2. REPAIR CLASSIFIED AS MAJOR PER FEDEX GMM 6-2-100. REPETITIVE INSPECTION REQUIRMENT- INITIAL AT 1,500 CYCLES AND AT INTERVAL 1,500 CYCLES TO BE CARRIED OUT AS PER MD-11 SRM 53-10-14-2R TABLE 201 / REPAIR 2.