What was found
WHILE ACCOMPLISHING RIGHT HAND NUMBER 4 BANJO FITTING INSPECTION AS PER WORK CARD T1-5530-49623C P4, LEFT HAND FORWARD LOWER SPAR RADIUS FOUND CRACK BETWEEN LOWEST TWO FASTENERS STATION Y = 2164. CRACK AT LEFT HAND FORWARD LOWER SPAR RADIUS BETWEEN LOWEST TWO FASTENERS STATION Y= 2164 REPAIRED PER E.A. #1-5530-T0373036 P1. TITLE: STABILIZERS - VERTICAL STABILIZER - CRACK REPAIRS ON VERTICAL STABILIZER REAR SPAR LHS & RHS FORWARD FLANGES. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.