What was found
LH OB FLAP LWR SURFACE FROM OB TO IB 98 INCH CROSS TE TO LE 8 INCH FOUND ONE DENT LH O/B FLAP LWR SURACE FROM O/B TO I/B 98 INCH CROSS T/E TO L/E 8 INCH DENT DAMAGE SIZE: L XW=1.7" X 1.5", OUT OF ALLOWABLE LIMIT PER B777 SRM 57-53-01-1A ALLOWABLE DAMAGE 2, REV43.1, REPAIRED AS PER WORK CARD TG-5750-T0372810, TITLE: WING-FLIGHT SURFACES-LH OUTBD FLAP TE WEDGE DENT WITH DELAMINATION AT OTEF STA 424-SRM REPAIR -RSC TRACKING. DETAIL PLS REFER TO WRI: 57504564. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2- 100.