What was found
DURING HIGH FREQUENCY EDDY CURRENT INSPECTION CARRIED OUT AT LEFT HAND WING FIXED LEADING EDGE AT TRACK NUMBER 9 OF XOS 602.6502, FOUND CRACK AT CORNER #11 APPROXIMATELY 1/4 INCH LENGTH. CRACKED SKIN AT LEFT HAND WING FIXED LEADING EDGE TRACK NUMBER 9 OF XOS 602.6502, AT CORNER #11 AREA REPAIRED AS PER SRM 57-40-01-2R REPAIR 18 FIGURE 201. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100. INITIAL INSPECTION TO BE CARRIED OUT AT NEXT C CHECK NOT EXCEEDING 24 MONTHS AND REPETITIVE INSPECTION EVERY C CHECK NOT EXCEEDING 24 MONTHS. METHOD: VISUAL AS PER SRM 57-40-01-2R TABLE 204 FIGURE 201/REPAIR 18.