What was found
FUSELAGE INTERNAL STRUCTURE - FRAME 14 FOUND CRACK SIGNAL AT JUNCTION AREA OF MAIN DECK FLOOR BEAM AND CRUCIFORM FITTING, RH SIDE, BY ULTRASONIC INSPECTION COMPLIED WITH EA: 6-5310-T0373313 P1. TITLE: FUSELAGE - MAINFRAME - CRACK HOLE FOUND ON FRAME 14 STRG 26 RH. REPAIRED THE FUSELAGE INTERNAL STRUCTURE FRAME 14 CRACK AT JUNCTION AREA OF MAIN DECK FLOOR BEAM AND CRUCIFORM FITTING, RH SIDE. THIS IS CATEGORY B REPAIR. FOLLOW UP INSPECTION PER EA: 6-5310-T0373313. MAJOR REPAIR IAW FEDEX GMM6-2-100. SEE WRI 53-10/3829 FOR WORK DETAILS.