What was found
UPON ARRIVAL FOUND DENT ON RT BS 132.21 BETWEEN F/O WINDOW & RADOME. SRM 53-00-01-1A. DENT IS 5 IN FROM RADOME CUTOUT, MEASUREMENT FOUND WIDTH 3.5 INCH, LENGTH 6 INCH AND DEPTH 0.11 INCH. REF. FIG 102 DETAIL E. NDTM PT6 PERFORMED HFEC OF SKIN CUTOUT AND INTERCOSTAL, ALSO PERFORMED HFEC ROTO-PROBE OF OPEN HOLES IAW NTM 51-00-01 PART 6. NO DEFECTS NOTED. SRM 53-00-01-2R FABD DOUBLER & FILER, TREATED & PRIMED IAW SRM 53-00-01-2R REPAIR 5 IAW EA G-5330-T0373214. SRM 53-00-01-2R. INSTALLED REPAIR IAW SRM 51-00-01-2R IAW EA 5330-T0373214. AMM: 51-21-10-07 APPLIED FINSH TO REPAIR DOUBLER IAW AMM 51-21-10-07. SRM: 53-00-01-2R COMPIED WITH EA G-5330- T0373214 REV A PART 5.