What was found
R/H LOWER HORIZONTAL FILLET PANEL LIGHT SURFACE CORROSION AT APPROX. STATION 2123, LONGERON 33R. INSTALLED FABRICATED DOUBLER IAW E.A.1-5330-T0373990. BLENDED OUT CORROSION REF MD11 SRM 53-00-00-2R FIGURE 202 SHEET 03. *MAJOR REPAIR*
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R/H LOWER HORIZONTAL FILLET PANEL LIGHT SURFACE CORROSION AT APPROX. STATION 2123, LONGERON 33R. INSTALLED FABRICATED DOUBLER IAW E.A.1-5330-T0373990. BLENDED OUT CORROSION REF MD11 SRM 53-00-00-2R FIGURE 202 SHEET 03. *MAJOR REPAIR*