What was found
DURING HFEC SURFACE INSPECTION ON THE LEFT HAND NOSE LANDING GEAR TRUNION FITTING AFT OF NOSE LANDING GEAR DOOR AFT HINGE FITTING SLOT OUT AREA FOUND 01 EACH CRACK WITH LENGTH APPROXIMATETLY 0.1 INCHES AT STATION 583 AS MARKED. LEFT HAND NOSE LANDING GEAR TRUNION FITTING AFT OF NOSE LANDING GEAR DOOR AFT HINGE FITTING SLOT OUT AREA, 01 EACH CRACK WITH LENGTH APPROXIMATELY 0.1 INCHES AT STATION 583 REPAIRED PER MD-11 SRM 53-10-14-2R REPAIR 2 FIGURE 202. REPETITIVE INSPECTION REQUIRED, INITIAL AT 1,500 CYCLES AND REPETITIVE INSPECTION AT 1,500 CYCLES TO BE CARRIED OUT PER MD-11 SRM 53-10-14-2R TABLE 201 REPAIR 2 FIGURE 202. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.