What was found
DURING HFEC INSPECTION ON RIGHT HAND WING FUEL ACCESS DOOR FORWARD INBOARD CORNER AT STATION XOS 610 FOUND 01 EACH CRACK APPROXIMATELY 0.3 INCHES. REPAIR CARRIED OUT AS PER MD - 11 SRM 57-40-01-2R REPAIR 18 FIGURE 201. INITIAL INSPECTION TO BE CARRIED OUT AT NEXT C CHECK NOT EXCEEDING 24 MONTHS AND REPETITIVE INSPECTION TO BE CARRIED OUT AT EVERY C CHECK NOT EXCEEDING 24 MONTHS PER MD-11 SRM 57-40-01-2R TABLE 204 REPAIR 18. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2- 100.