What was found
06 EACH FASTENER HOLE #7,#10,#11,#16,#37,#38 FOUND CRACK INDICATION DURING OPEN-HOLE HIGH FREQUENCY EDDY CURRENT INSPECTION AT LEFT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS=683.4 AND STATION XORS=713.6. LEFT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS=683.4 AND STATION XORS=713.6 REPAIRED AS PER SRM 57-2-02-2R FIGURE 201 REPAIR 5. INITIAL INSPECTION TO BE CARRIED OUT AT 2000 FLIGHT CYCLES AND REPETITIVE INSPECTION TO BE CARRIED OUT AT EVERY 2000 FLIGHT CYCLES BY HIGH FREQUENCY EDDY CURRENT AND ULTRASONIC INSPECTION AS PER SRM 57-20-02-2R FIGURE 202 REPAIR 5 TABLE 201. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.