What was found
1EA WATER TRAPPED AREA(130MMX120MM) WAS FOUND AT RUDDER R/H T/E SCREW LINE NO.39 FASTENER AREA ACCOMPLISHED THE COMPOSITE REPAIR, THIS IS CAT.B REPAIR I.A.W A300-600 SRM 55-41-12-201, PARA.31, PAGE.313-319, FIG.222 & SRI:55-41-12-201, IIR:55-41-12-2-006-00, PARA.3F, PAGE.221-224, TABLE.207 "MAJOR REPAIR"