What was found
LH OB FLAP LWR SURFACE FROM IB TO OB 110INCH CROSS TE TO LE 6.2INCH FOUND ONE DENT. EVALUATED LH OB FLAP LWR SURFACE FROM IB TO OB 110INCH CROSS TE TO LE 6.2INCH DENT DAMAGE SIZE LXW=3.1"X1.5" OUT OF ALLOWABLE LIMIT AS PER B777 SRM 57-53-01-1A ALLOWABLE DAMAGE 2 REV 44.0 ,REPAIRED THE DAMAGE AS PER B777 SRM 57-53-01-2R-2 REPAIR 2 AND SRM 51-70-04-2R -1 REPAIR 1 AND SRM 51-70-04-2R REPAIR GENERAL REV 44.0 AND EA G-5750-T0374694 P1 ,TITLE :WING-FLIGHT SURFACES -LH OUTBD FLAP TE WEDGE DENT WITH DELAMINATION AT OTEF STA 142-SRM REPAIR -RSC TRACKING ,DETAIL PLS REFER TO WRI 57503598,REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.