What was found
RUDDER , R/H EXTERNAL SURFACE IS DELAMINATED APPROX 8FT UP FROM THE FUSELAGE APPROX 27" FWD OF THE AFT EDGE REPAIRED RUDDER , R/H EXTERNAL SURFACE , APPROX 8FT UP FROM THE FUSELAGE , APPROX. 27" FWD OF THE AFT EDGE BY REMOVING DAMAGE , CLEANING , LAYING UP REPAIR PLIES AND CURED . IAW B767-SRM 55-40-01-2R FIG. 201 , DETAIL 1 AND SRM 51-70-17-0G , RESTORED FINISH IAW B767 SRM 51-70-17-0G PAR. 3H (2)