What was found
RUDDER , R/H EXTERNAL SURFACE IS DELAMINATED APPROX 8FT UP FROM THE FUSELAGE APPROX 10" FWD OF THE AFT EDGE REPAIRED R/H EXTERNAL SURFACE OF RUDDER APPROX 8FT UP FROM THE FUSELAGE ,APPROX 10" FWD OF AFT EDGE BY REMOVING DAMAGE , CLEANING AREA , LAYING UP REPAIR PLIES AND CURED , IAW B767 SRM 55-40-01-2R FIG 201, DETAIL I AND SRM 51-70-17-0G . RESTORED FINISH IAW B767 SRM 51-70-17-0G PAR. 3. H (2)