What was found
L/H HOR. STAB, UPPER SKIN IS DENTED AND GOUGED AT APPROX 75" O/B OF STAB ROOT JUST AFT OF L/E PANEL 332BL REPAIRED L/H HOR STAB, UPPER SKIN DENT AND GOUGE APPROX 75" O/B OF THE STAB ROOT, JUST AFT OF L/E PANEL 332BL AS REQUIRED IAW FDX B767 SRM 51-70-10-2R AND RESTORED FINISH AS REQUIRED IAW B767 AMM 51-21-10