What was found
DURING HFEC SURFACE INSP ON LT SIDE FORWARD FLANGE OF LOWER VERTICAL STAB REAR SPAR CAP, NR 4 BANJO FITTING UPPER SECTION AT STA Y=2164, FOUND CRACK ALONG RADIUS FROM LOWEST FASTENER TOWARDS THE 2ND FASTENER WITH LENGTH APPROXIMATELY 0.5 INCH. TRIMMED AS PER MD-11 SRM 55-30-02-2R FIGURE 201 REPAIR 5 AND REPAIRED AS PER MD-11 SRM 55-30-02-2R FIGURE 202 REPAIR 5. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100. TO CARRY OUT INITIAL INSPECTION AT 5,400 FLIGHT CYCLES AND REPETITIVE INSPECTION AT EVERY 2,700 FLIGHT CYCLES AS PER MD-11 SRM 55-30-02-2R TABLE 203 REPAIR 5 FIGURE 202. REQUIREMENTS METHOD BY ULTRASONIC AND HIGH FREQUENCY EDDY CURRENT PER SN10550000 REQUIREMENTS.