What was found
DURING HFEC SURFACE INSP ON RT SIDE, FWD FLANGE OF LOWER VERTICAL STAB REAR SPAR CAP, NR 4 BANJO FITTING UPPER SECTION AT STA Y=2164, FOUND CRACKED ALONG RADIUS BETWEEN LOWEST FASTENER & 2ND FASTENER WITH LENGTH APPROX 0.75 INCH. TRIMMED IAW SRM 55-30-02-2R FIGURE 201 REPAIR 5 & REPAIRED IAW SRM 55-30-02-2R FIGURE 202 REPAIR 5. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100. TO CARRY OUT INITIAL INSPECTION AT 5,400 FLIGHT CYCLES AND REPETITIVE INSPECTION AT EVERY 2,700 FLIGHT CYCLES AS PER MD-11 SRM 55-30-02-2R TABLE 203 REPAIR 5 FIGURE 202. REQUIREMENTS METHOD BY ULTRASONIC & HFEC IAW SN10550000 REQUIREMENTS.