What was found
MAIN DECK FLOOR STRUCTURE SHEAR WEB CRACK NEAR FR79 PLUS 5" ,-Y1620. REMOVED CRACK SHEAR WEB THEN INSTALLED NEW ONE WITH FASTENERS I.A.W A300-600F SRM 51-72-10-001,PAGE 2 AND 51-40-21-001,PAGE 24-50,PARA.7
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOOR STRUCTURE SHEAR WEB CRACK NEAR FR79 PLUS 5" ,-Y1620. REMOVED CRACK SHEAR WEB THEN INSTALLED NEW ONE WITH FASTENERS I.A.W A300-600F SRM 51-72-10-001,PAGE 2 AND 51-40-21-001,PAGE 24-50,PARA.7