What was found
DURING ACCOPLISHMENT OF SNRM NO: N00708, HIGH FREQUENCY EDDY CURRENT INSPECTION CARRIED OUT AND FOUND ADDITIONAL 02EA CRACK APPROXIMATELY 0.25 INCH AND 0.5 INCH AS MARKED PROPAGATE FROM THE LOWER FASTENER HOLE OF LOWER INTERNAL LONGERON REVEAL BY THE TRIMMED OUT AREA AT RIGHT HAND NOSE LEADING GEAR TRUNNION FITTING AFT OF NOSE LEADING GEAR DOOR AFT HINGE SLOT OUT AREA AT STATION 583. CRACKED LONGERON AT RIGHT HAND NOSE LANDING GEAR TRUNNION FITTING AFT OF NOSE LANDING GEAR DOOR STATION 583 REMOVED AND REPLACED IN ACCORDANCE WITH SRM 51-31- 01-0G. LONGERON FABRICATED IN ACCORDANCE WITH DOUGLAS DRAWING # ACA 3796 REVISION A. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100.