What was found
EXISTING REPAIR ON MAIN DECK COMPT SEAT TRACK AT FR28-FR30, Y450 REQUIRES EVALUATION FOR CONFORMITY THE EXISTING REPAIR ON MAIN DECK COMPT SEAT TRACK AT FR28 - FR30, Y450 WAS EVALUATED AND FOUND NOT CONFORMITY WITH A300-600F SRM53-10-16 FIG.201. REPORTED IT TO FEDEX ENGINEER AND REPAIRED IT PER A300-600F SRM53-10-16 FIG.201. EO: 6-5100-7-5000 D7 PT1 WAS COMPLETED TITLE: STRUCTURES - REPAIR CATALOG - A300/A310 REPAIR IDENTIFICATION & TRACKING REQUIREMENTS 14 CFR121.707. THE REPAIR WAS CATEGORY "A" AND WAS CLASSIFIED AS MAJOR PER GMM6-2-100