What was found
LH WING #5 SPOILER CENTER O/B HINGE LOWER SURFACE (17MM*12MM, DEPTH: 1.7MM) AND O/B SIDE (30MM*10MM, DEPTH: 1.1MM) FOUND DELAMINATION REPAIRED LH WING #5 SPOILER CENTER O/B HINGE O/B SIDE DELAMINATION PER SB A300-57-6082 R03 FIGURE 2 SHEET 2&4 AND FIGURE 5, AND COMPARED & ENSURED LH WING #5 SPOILER CENTER O/B HINGE LOWER SURFACE DELAMINATION IS WITHIN THE ALLOWABLE REPAIR LIMITS IN THE INSPECTION SB A300-57-6083 R04 FIGURE 4 SHEET 1&2 PER EA 6-5750-T0376849 P1 THIS IS CAT A REPAIR. MAJOR REPAIR IAW FEDEX GMM6-2-100. SEE WRI 57- 50/5812 FOR WORK DETAILS.