What was found
MAIN CABIN FLOOR BEAM AT STA 880 LBL 48 TO 62 LBL SURFCE CORROSION. DOT 101. ACCOMPLISHED EA F-5321-T0376857 P1 "FUSELAGE MAINFRAME SECTION 43, FLOOR BEAM ASSY CORROSION, STA879, UPPER CHORD, LBL 45-58, DEVIATION FROM TYPICAL SRM REPAIR, WITH NO DEVIATION.