What was found
UPPER MAIN DECK FLOOR STRUCTURE, AS SEEN FROM BEHIND THE LOWER BULK CARGO, FLOOR PANEL ATTACH STRUCTURE BETWEEN STATION 1564 AND 1582, RBL 78, "I" BEAM REINFORCE "L" ANGLE ON OUTBOARD SIDE OF "I" BEAM IS CRACKED. REMOVED AND REPLACED ANGLE BRACKET REF 767 DWG 146T5650, AND 767 SRM 51-40-02-0G. MINOR REPAIR.