As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CABIN - RIGHT HAND FLOOR PANEL #272EF VIEW PORT CUTOUT HOLE FOUND DAMAGE AT STATION 1381, X = - 50. CABIN - DAMAGED RIGHT HAND FLOOR PANEL #272EF AT STATION 1381, X = - 50 REMOVED AND REPLACED AS PER MD-11 AMM 53-21-04-4. RIGHT HAND FLOOR PANEL #272EF FABRICATED AS PER FEDEX DRAWING SRZ-25-005 REVISION R. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.