What was found
MAIN DECK FLOOR ONE SUPPORT CRACK NEAR FR38.1 PLUS 5" STGR26R. REPLACED THE NEW SUPPORT. I.A.W A300-600 SRM 51-72-10-001,P2 NEAR FR38.1 PLUS 5" STGR 26R. THIS REPAIR CLASSIFIED AS MINOR PER GMM 06-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOOR ONE SUPPORT CRACK NEAR FR38.1 PLUS 5" STGR26R. REPLACED THE NEW SUPPORT. I.A.W A300-600 SRM 51-72-10-001,P2 NEAR FR38.1 PLUS 5" STGR 26R. THIS REPAIR CLASSIFIED AS MINOR PER GMM 06-2-100.