What was found
[UPPER MAIN DECK FLOOR STRUCTURE, AS SEEN FROM BEHIND THE LOWER BULK CARGO, FLOOR PANEL ATTACH STRUCTURE BETWEEN STATION 1564 AND 1582, LBL 78, "I" BEAM REINFORCE "L" ANGLE ON OUTBOARD SIDE OF "I" BEAM IS CRACKED., 2024-03-08] REMOVED AND REPLACED ANGLE P/N 146T5651-7 PER BOEING DWG 146T5650 AND SRM 51-40-02-0G. SEE JPF FOR REMOVAL AND INSTALLATION STEPS. MINOR REPAIR.