What was found
L-1 ENTRY DOOR UPPER SIDE OF THE FLOOR SUPPORT AT STA 339 LBL 60 FOUND CORROSION. REMOVED CORROSION AT L-1 ENTRY DOOR STA 339 LBL 60 ON FLOOR SUPPORT IAW B757 SRM 51-10-02-0G, OUT OF LIMITS IAW B757 SRM 53-10-15-1A DETAIL IV FIG 101, REMOVED AND INSTALLED FLOOR SUPPORT IAW B757 SRM'S 51-40-02-0G, 51-40-05-0G ABD B DWG# 141N5170 REV C & F ITEM -39 MAJOR REPAIR