What was found
HIGH FREQUENCY EDDY CURRENT INSPECTION ON NOSE LANDING GEAR LEFT HAND SIDE TRUNNION FITTING STATION 595 EXISTING TRIMMED OUT AREA FOUND CRACK APPROXIMATELY 0.35". NOSE LANDING GEAR LEFT HAND SIDE TRUNNION FITTING STATION 595 CRACKED AREA CARRIED OUT REPAIR IN ACCORDANCE WITH EA # 1-5310-T0378563 P1 TITLE : FUSELAGE - MAINFRAME -CRACK REPAIR ON LH NOSE LANDING GEAR TRUNNION FITTING, STA 595. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.