What was found
AVIONICS COMP'T CABIN FLOOR STRUCTURE CROSSBEAM 1EA ANGLE FITTING CRACK AT FR10,Y- 953 POSITION. REPLACED THE NEW ANGLE WITH RIVETS I.A.W A300-600F SRM 51-72-10-001, PAGE.2 & 51-40-21- 001, PARA.6, PAGE.7B-PAGE.23,THIS REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 AND LOCATED AT AVIONICS COMP'T AT FR10 Y-953 POSITION