What was found
CABIN - STATION 1887, X = 24 FLOOR SUPPORT APPROXIMATELY OF 1.50 INCH FOUND CRACK. CABIN AT STATION 1887, X = 24 CRACKED FLOOR SUPPORT REMOVED AND REPLACED AS PER MD-11 SRM 51-31-01-0G AT STATION 1887 TO STATION 2007, X = 24. FLOOR SUPPORT FABRICATED BY MACHINING AS PER DOUGLAS DRAWING AGA 7087 REVISION M. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100. FOR PART NUMBER EFFECTIVITY E.A.#: 1-5321- T0379171, TITLE: FUSELAGE - CARGO COMP FLOORS - IPC 53-00-40-01 AND IPC 53-21-43-03,