What was found
ON CLIMB OUT GREENS SYSTEM HYDRAULIC ECAM SHOWED LOW QUANTITY. FOLLOWED ECAM PROCEDURES AND QRH. MANUAL GEAR EXTENSION AND SAFELY LANDED AIRCRAFT. TOWED OFF RUNWAY TO PARKING. FOUND GREEN SYSTEM ACCUMULATOR READING APPROXIMATELY 200 PSI. ATTEMPTED TO SERVICE PER ABOVE REFERENCE. NOTED HYDRAULIC FLUID LEAKING FROM SCHRADER VALVE SERVICE POINT. SUSPECT BAD ACCUMULATOR. ITEM REMAINS IN WORK. RESTORED SYSTEM TO NORMAL OPERATING CONDITION AFTER LANDING GEAR FREE FALL EXTENSION IAW AMM 32-33-00-02. REMOVED AND REPLACED GREEN HYD ACCUMULATOR IAW AMM 29-11-56-04, OPS AND LEAK CHECK GOOD AT THIS TIME. PERFORMED VISUAL CHECK OF EDP DPI'S IAW AMM 29-00-00-03, NO FAULTS NOTED. RAN ENGINES IAW JRH CH 05, WITH NO FAULTS NOTED. A/C OK TO CONTINUE. PER GMM 12-7-600.