What was found
MAIN DECK FLOOR STRUCTURE SHEAR WEB CRACK AT FR79 5", -Y1620 POSITION REPLACED SHEAR WEB WITH FASTENERS AT FR79 5",-Y1620 POSITION, I.A.W A300-600 SRM 51-72- 10-001,PAGE 2 & 51-40-21-001, PARA.7,PAGE 24~50
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOOR STRUCTURE SHEAR WEB CRACK AT FR79 5", -Y1620 POSITION REPLACED SHEAR WEB WITH FASTENERS AT FR79 5",-Y1620 POSITION, I.A.W A300-600 SRM 51-72- 10-001,PAGE 2 & 51-40-21-001, PARA.7,PAGE 24~50