What was found
MAIN DECK FLOOR STRUCTURE SHEAR WEB CRACK AT FR79 PLUS 5",-Y1620 POSITION REPLACED SHEAR WEB WITH FASTENERS AT FR79 PLUS 5",-Y1620 POSITION, I.A.W A300-600 SRM 51-72-10-001,PAGE 2 & 51-40-21-001, PARA.7,PAGE 24~50 THE REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100 NOTE: THE SDR NO: 24-0733 SEVERAL TYPO, THIS SDR ITEM 5.(A)& (C) TYPE ERROR,CREATE NEW SDR NO: 24-0737