What was found
DURING ACCOMPLISHING WORKCARD 57.11.01.1, FOUND CRACK ON CENTER UPPER AUXILLARY TANK STRINGER 46 AT STATION XCW 17. CENTER UPPER AUXILLARY TANK STRINGER 46 AT STATION XCW 17 CRACK AREA REPAIRED AS PER EA 1-5710-T0379885 PART 1 TITLE: WINGS-BASIC WING STRUCTURE-CENTER WING LOWER PANEL CRACK FOUND ON STRINGER S-46 AT XCW 17.000. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100. CENTER UPPER AUXILLARY TANK FUEL LEAK CHECK CARRIED OUT FOUND SATISFACTORY AS PER AMM 12-11-04-2.