Service difficulty report · Circuit Card · Boeing 7673S2F

Difficulty date
July 15, 2024
Submitted
July 17, 2024
Operation
Air carrier
Aircraft
N107FE
Make and model
Boeing 7673S2F
Aircraft serial
44377
Aircraft time
19,817 hours, 7,977 cycles
Part
Circuit Card
Part number
285T025919
Condition
Failed
Location
Fire Detection
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FIRE WARNING BELL CAME ON AT ROTATION. NO OTHER INDICATIONS. BELL WILL NOT SILENCE EVEN AFTER BLOCK IN AND ENGINES SHUTDOWN. MDIS 31-50 1103. REF. FIM 31-51 TASK 801, DID A WEU BITE & RESET.TEST NORMAL IAW AMM 31-51-00-5, PERFORMED FIRE BELL WARNING SIGNALS TEST. TEST NORMAL INSPECTED BELL/CHIME MODULE M1000 IN P51. PAID ATTENTION TO CONDITION OF CONNECTORS & PINS. MADE SURE CARD WAS PROPERLY SEATED IAW AMM 31-51-04. INSPECTED NORMAL. REPLACED BELL/CHIME MODULE M1000 IAW AMM 31-51-04-4. MADE SURE THE CARD IS PROPERLY SEATED IAW AMM 31-51-04-4. PERFORMED BELL/CHIME AURAL WARNING CARD MODULE TEST, TESTED NORMAL IAW AMM 26-14-00-5. PERFORMED MDCC SMOKE DETECTOR SAMPLING TUBES & SAMPLING TRUNK TUBE ORIFICES OPS TEST, TESTED NORMAL. REF AMM26-21-02-2 REPLACED THE ENGINE FIRE CONTROL PANEL. REF AMM26-21-01-716-001 DID ENGINE FIRE SWITCH OPS CHECK, RESULT :TEST NORMAL. REF AMM26-21-02-2 DID ENGINE FIRE CONTROL PANEL INSTALLATION TEST, RESULT :TEST NORMAL REF AMM26-11-01-4. REPLACED THE FIRE/OVERHEAT TEST PANEL. REF AMM26-11-01-4. DID INSTALLATION TEST, TESTED NORMAL. REF AMM31-51-04-4 REPLACED THE T/O CONFIGURATION WARNING MODULE IAW AMM31-51-04-4. DID TEST , TEST NORMAL. REF AMM32-09-02-2. REPLACED THE RELAY K219, TEST NORMAL. RESTORE AC TO SERVICE. ORIGINAL SUBMISSION DATE: 7/16/2024

More about the Boeing 767-3S2F