What was found
MAIN DECK FLOOR SHEAR WEB CRACK AT FR79 PLUS 5" -Y1620 REPLACED THE CRACK SHEAR WEB BY NEW ONE WITH FASTENERS AT MAIN DECK FLOOR FR79 PLUS 5", -Y1620, I.A.W A300-600F S.R.M 51-72-10-001 AND 51-40-21-001 PARA.7, PAGE.24~50. THIS REPAIR CLASSIFIED AS MINOR PER G.M.M 6-2-100