What was found
RIGHT AFTER TAKING THE RUNWAY FOR TAKEOFF, PRIOR TO ENGINE RUN UP, GOT A GEN 1 FAULT. ATTEMPTED ONE RESET IAW QRH/ECAM, BUT FAULTED AGAIN. AMM: 24-22-18-04 ESPM: 20-46-50 REMOVED AND REPLACED TRANSFER CONTACTOR 11XU AND LINE CONTACTOR CONTROL RELAY 13XU REF ABOVE. TESTS GOOD USING EXTERNAL POWER.