What was found
FOUND CRACK INDICATION DURING HFEC INSPECTION, APPROXIMATELY 0.25 INCH IN LENGTH, AT LEFT HAND NOSE LANDING GEAR TRUNNION FITTING LOWER SECTION STATION Y=595 ON EXISTING SLOT OUT AREA. CRACK AT LEFT HAND NOSE LANDING GEAR TRUNNION FITTING LOWER SECTION STATION Y=595 ON EXISTING SLOT OUT AREA, REPAIR ACCOMPLISHED PER E.A.#:1-5310-T0380699 P1 AND MD-11 SRM 53-10-14 REPAIR 2, FIGURE 202. TITLE: FUSELAGE MAINFRAME CRACK REPAIR ON LH NOSE LANDING GEAR TRUNNION FITTING, STA 595. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2- 100.