What was found
REWORK SEQ:N00164 THIS TASK MUST BE REPEATED INSPECTOR IS NOT RII N00164 WAS REWORKED: MAIN DECK FLOOR PANEL 241GFF BTW STA 731.11 TO STA 933 WAS REPAIRED IAW B767 SRM 53-00-50-2R PAR 4.B FIG 201 SHEET 2 REV 90 AUG 15/2024
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
REWORK SEQ:N00164 THIS TASK MUST BE REPEATED INSPECTOR IS NOT RII N00164 WAS REWORKED: MAIN DECK FLOOR PANEL 241GFF BTW STA 731.11 TO STA 933 WAS REPAIRED IAW B767 SRM 53-00-50-2R PAR 4.B FIG 201 SHEET 2 REV 90 AUG 15/2024