What was found
AFT CARGO / WASTE TANK COMPARTMENT - EXISTING REPAIR FOUND AT THE PRESSURE BULKHEAD UPPER TEE STATION 2007, X = 34 REQUIRES EVALUATION FOR CONFORMITY TO APPROVED DATA EXISTING REPAIR AT AFT CARGO / WASTE TANK COMPARTMENT PRESSURE BULKHEAD UPPER TEE STATION 2007, X = 34 EVALUATED AND FOUND REPAIRED IAW SRM 53-70-08-2R REPAIR 4 FIGURE 201. EO 1-5100-7-5001 B7 PART 1 TITLE STRUCTURES - REPAIR CATALOG - MD-11 REPAIR IDENTIFICATION & TRACKING REQUIREMENTS 14 CFR 121.707 ACCOMPLISHED. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.