What was found
GREEN HYDRO QUANTITY ALERT ON ECAM, INDICATING RED DOT. QUANTITY INDICATION INCREASED TO AND REMAINED JUST ABOVE YELLOW ARC AT GEAR EXTENSION, REMAINING SAME AT SHUTDOWN. FOUND L/H ELEVATOR GREEN SYSTEM HYDRAULIC ACTUATOR LEAKING AT PRESSURE LINE B-NUT. TIGHTEN B-NUT TO SPECS IN REF A300-600 AMM 20-23-12-00. LEAK CHECKED GOOD. SERVICED HYDRAULIC SYS IAW AMM 12-12-29-00. A/C OK FOR SERVICE.