What was found
L1 DOOR HINGE S BROKEN INITIAL INSPECTION APPEARS THAT LOWER ARM ASSY - GUIDE-HINGE MECH" DETACHED FROM THE DOOR, THE 4 BOLTS THAT HELD THE SERRADED PLATE ATTACHED TO THE ARM BACKED OUT. RELEASED FOR SERVICE PER MEL : 52-11-01-A CATEGORY : B. L1 DOOR - INOP. COMPLIED WITH EA F-5210-T0380893 P1, THE BOLTS THAT SECURE THE GUIDE ARM PLATE TO THE DOOR COULD ONLY SNUG AT BEST, MOCC AND ENGINEER TIMOTHY STACKS ARE OK WITH THIS CONDITION FOR CONDITIONAL DISPACH. UPON ARRIVAL, FOUND BOLTS INSTALLED WERE TOO SHORT. INSTALLED LONGER APPLICABLE BOLTS (P/N: BACB30NM4K13) AND WASHERS PER ABOVE IPC REFERENCE. TORQUED BOLT AS REQUIRED. DOOR RIG CORRECT PER ABOVE AMM REFERENCE. OPS CHECK GOOD A/C OK FOR SERVICE.