What was found
MAIN DECK FLOOR STRUCTURE FOUND SEAT TRACK CORROSION AT FR15A 2" AND Y953 AREA REPLACED THE DAMAGE SEAT TRACK WITH NEW ONE AT MAIN DECK FLOOR STRUCTURE FR15A PLUS 2" AND Y953 AREA I.A.W A300-600F SRM 51-72-10-00, PAGE 2 & 51-40-21-001, PARA.6 PAGE 7B- PAGE 23. THIS REPAIR CLASSIFIED AS MINOR PER GMM 06-2-100.