What was found
EXISTING REPAIR ON MAIN DECK FLOOR SUPPORT AT Y730 BETWEEN FR11 AND FR13A REQUIRES EVALUATION FOR CONFORMITY THE EXISTING REPAIR ON MAIN DECK SUPPORT AT Y730 BETWEEN FR11 AND FR13A WAS EVALUATED AND FOUND CONFORMITY WITH DWG: A53612214(ISSUE.V00), BUT THE CORROSION WAS FOUND, REPLACED IT WITH FLOOR SUPPORT PER DWG: A53612214(ISSUE.V00). EO 6-5100-7- 5000 D7 PT1 WAS COMPLETED, TITLE: STRUCTURE - REPAIR CATALOG - A300/A310 REPAIR IDENTIFICATION & TRACKING REQUIREMENTS 14 CFR121.707. THE REPAIR WAS CATEGORY "A" AND WAS CLASSFIED AS MAJOR PER GMM6-2-100.