What was found
2EA WATER TRAPPED AREAS (470MM*100MM, 50MM*80MM) WERE FOUND AT R/H ELEVATOR TOP SKIN PANEL T/E AREA, BETWEEN FASTENER NO.9 TO NO.11 *COUNTING T/E FASTENER FROM I/B TO O/B* ACCOMPLSIEHD THE COMPOSITE REPAIR AT RH ELEVATOR TOP SKIN TRAILING EDGE BETWEEN FASTENER NO.9 AND NO.11 I.A.W A300-600F SRM 55-21-12-201, PARA.5B&5F&5J, PAGE.211~214&241~256&268~274, FIG.202&208~209&212 AND FEDEX EA NO:T6-5520-T0381400 P1, SEQ NO:965, TITLE:STABILIZERS - ELEVATORS - RH ELEVATOR - SRM COMPOSITE REPAIRS ON UPPER AND LOWER SKINS - RSC TRACKING. THE REPAIR CLASSIFIED AS CAT.B MAJOR PER GMM 6-2-100.