What was found
1EA WATER TRAPPED AREA (90MM*340MM) WAS FOUND AT R/H ELEVATOR BOTTOM SKIN PANEL T/E AREA, BETWEEN FASTENER NO.10 TO NO.12. *COUNTING T/E FASTENER FROM I/B TO O/B* ACCOMPLSIEHD THE COMPOSITE REPAIR AT RH ELEVATOR LOWER SKIN TRAILING EDGE BETWEEN FASTENER NO.9 AND NO.12 I.A.W A300-600F SRM 55-21-12-201, PARA.5B, PAGE.211~214, FIG.202 AND FEDEX EA NO:T6-5520-T0381400 P1, SEQ NO:965, TITLE:STABILIZERS - ELEVATORS - RH ELEVATOR - SRM COMPOSITE REPAIRS ON UPPER AND LOWER SKINS - RSC TRACKING. THE REPAIR CLASSIFIED AS CAT.B MAJOR PER GMM 6-2-100.