What was found
MAIN DECK FLOOR STRUCTURE SEAT TRACK FOUND CORROSION NEAR FR15A, Y450 CUT THE FLOOR STRUCTURE AND FABRICATED THE REPAIR ANGLE AND FLOOR SUPPORT. INSTALLED REPAIR PART WITH NEW FASTENERS AT MAIN DECK FLOOR STRUCTURE SEAT TRACK NEAR FR15A, Y450. I.A.W A300-600F SRM 53-12-16-201, PARA.5A, PAGE.203~206, FIG.201, SHEET1~2 (CONFIG-2) , THE REPAIR IS CATEGORY B AND CLASSIFIED AS MAJOR PER GMM 6-2-100& A300- 600F SRI 53-12-16-201, PARA.3A, TABLE.202; IIR 53-12-16-2-001-00