What was found
MAIN DECK FLOOR STRUCTURE WAS FOUND PLATE SHEAR CRACK AT FR79 PLUS 4", S-26L REPLACED THE DAMAGE PART WITH NEW ONE AND INSTALLED WITH FASTENERS. I.A.W A300-600 SRM 51-72-10-001, PAGE 2 AND SRM 51-40-21-001, PARA 7, PAGE 24~50. THIS REPAIR IS CATEGORY A AND CLASSIFIED AS MINOR PER GMM 06-2-100. AT MAIN DECK FLOOR STRUCTURE FR79 PLUS 4", S-26L