What was found
MDCC UNDER FLOOR PANEL - FR47, Y953-Y1456 FOUND 1EA WEB CRACKED. REPAIRED THE CRACKED WEB AT MDCC UNDER FLOOR PANEL FR47, Y953-Y1456 PER A300-600F SRM53-15-15-201 FIG201. THIS IS CAT B REPAIR AND MUST BE INSPECTED AT DEFINED INTERVALS PER SRI53-15-15-2-002-00. INSPECTION THRESHOLD FROM REPAIR EMBODIMENT: 24000FC. SUBSEQUENT INSPECTION AT INTERVAL: 3000FC, INSPECTION METHOD: DVI. MAJOR REPAIR IAW FEDEX GMM6-2-100.