What was found
MAIN DECK FLOOR AREA LH SIDE @ STA 16-61 LOWER BEAM INTERCOSTAL HAS CRACK. CUTOUT AND REMOVED DAMAGE AREA (1.65") IAW SRM 53-00-51-2R PERFORMED HFEC SURFACE INSPECTION IAW NTM 51-00-19, NO CRACK NOTED. FABRICATED 01 EA STRAP AND 01 EA FILLER IAW SRM 53-00-51-2R, LOCATED AND DRILLED IAW SRM 53-00-51-2R, TREATED AND PRIMED IAW SRM 51-20-01-OG, INSTALLED NEW PARTS IAW SRM 53-00-51-2R, MARKED REPAIR PARTS IAW GMM 07-0-1001, MAJOR REPAIR